From: Jason Aarons (jaarons@xxxxxxxxxxx)
Date: Wed Aug 04 1999 - 20:26:51 GMT-3
   
On Router "2" I have two FR DLCI to other locations via the same cable.  Why
does s0.2 show down/line protocol down ?  Does the fr-switch need
sub-interfaces ?
hostname fr-switch
!
interface Serial2/1
no ip address
encapsulation frame-relay
clockrate 148000
frame-relay intf-type dce
frame-relay route 201 interface Serial2/0 101
frame-relay route 204 interface Serial2/2 202
2#show fr pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
DLCI = 201, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.1
  input pkts 83            output pkts 271          in bytes 6160
  out bytes 21479          dropped pkts 2           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 270        out bcast bytes 21411
  pvc create time 00:15:49, last time pvc status changed 00:00:17
DLCI = 204, DLCI USAGE = LOCAL, PVC STATUS = INACTIVE, INTERFACE = Serial0.2
  input pkts 0             output pkts 14           in bytes 0
  out bytes 1559           dropped pkts 0           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 14         out bcast bytes 1559
  pvc create time 00:15:50, last time pvc status changed 00:00:07
2#show int s0.1
Serial0.1 is up, line protocol is up
  Hardware is HD64570
  Internet address is 172.16.254.2/30
  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY
2#show int s0.2
Serial0.2 is down, line protocol is down
  Hardware is HD64570
  Internet address is 172.16.253.2/30
  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 08:21:46 GMT-3