Re: Token Ring Queries

From: Shaun Nicholson (Shaun.Nicholson@xxxxxx)
Date: Fri Nov 10 2000 - 15:43:21 GMT-3


   
The main thing I found to be an issue was the switch I had a 3920 was set to au
to detect duplex and speed. I changed this to full and 16 and it worked. The in
terface was up on the router however in my case but it would not work until har
d coded.

Shaun

Justin.Menga@computerland.co.nz on 11/09/2000 10:12:00 PM
To: ccielab@groupstudy.com@Internet
cc: (bcc: Shaun Nicholson/MD/KAIPERM)
Subject: Token Ring Queries

Hi,

Sorry, I have no experience with physical token ring, so forgive if these
are silly questions:

I have access to equipment that has DB-9 style female Token Ring interfaces.
I have a Catalyst 5500 Token Ring Switching Module that has 24 RJ-45 style
Token Ring ports.

I have cables that "look" like they convert from DB-9 to RJ-45, but I have
had trouble getting the interfaces to initialise. Here I my configs:

R1:

int to0
    no shut
    ring-speed 16

R2:

int to0
    no shut
    ring-speed 16

Catalyst:

set tokenring mode 10/1-24 auto
set vlan 1003 mode srt (this is the default TrCRF...)

Can anybody help with a minimum configuration?

Regards,

Justin Menga MCSE+I CCNP CCSE ASE
WAN Specialist
Computerland New Zealand
PO Box 3631, Auckland
DDI: (+64) 9 360 4864 Mobile: (+64) 25 349 599
mailto: justin.menga@computerland.co.nz



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 08:25:44 GMT-3