OT:ISP? frame-relay problem

From: @ Home NetMail (@)
Date: Mon Nov 26 2001 - 17:06:47 GMT-3


   
All,

Interesting real problem...any suggestions?

2 outside routers, separate T's and a Disaster recovery T, different
location.
Numerous spoke sites all have 3 pvc's, 1 to each of the above.
All are separate 255.255.255.248 mask's with subs on the hub's and DR. The
spokes are configured on the physical, and inverse-arp to map for control of
routes from the hub DR.

Newest 2 sites, when turned up in the above configuration take down ALL
production sites on both outside routers. If I sub serial the spoke on p-to-p,
it works. I have eliminated hardware, and because I have 50 or so other sites
up I have eliminated the configs. It may be a routing issue but since there
are
24x7 internet clients its quite difficult to analyze.

Can the ISP somhow loop the pvc's to each other?

Any help, suggestions?

TIA,
-Todd



This archive was generated by hypermail 2.1.4 : Fri Jun 21 2002 - 06:45:23 GMT-3