From: Peter Whittle (peter@xxxxxxxxxxxxxxxxxxxxxxxxxxx)
Date: Fri Feb 22 2002 - 16:49:11 GMT-3
   
Most certainly is!
If you connect them back to back via a T1 cross-over cable then you can
only practice ATM PVCs.
For SVCs you need an ATM switch with SVC call control processor and dual
T1 ATM interfaces.
I currently have a pair with the mft-T1/E1 re-configure as an E1 i/f (go
into ROMMON to change it). This does not matter to the ATM side of
things.
Config extract
        controller E1 0
         clock source internal
         mode atm
        interface ATM0
         ip address 172.31.69.9 255.255.255.0
         no atm ilmi-keepalive
         pvc 0/101
          protocol ip 172.31.69.6 broadcast
          encapsulation aal5nlpid
         !
Remember if you do not have an ATM switch then the vpi/vci must match at
both ends ie you must use the same at both ends.
eg rtr-A
        pvc 0/101
   rtr-B
        pvc 0/101
Peter
In message <4.3.2.7.2.20020222111032.03011ec8@overnight.cisco.com>,
Jaspreet Bhatia <jasbhati@cisco.com> writes
>Folks,
>                  Is it possible to run ATM on MC 3810 with MFT interfaces
>connected to each other back to back and would a T1 crossover cable do the
>trick? Thanks
>
>Jaspreet