From: Sam Peters (sampeters20@xxxxxxxxxxx)
Date: Fri Apr 05 2002 - 20:45:07 GMT-3


   
Are you running hybrid or native code?
1. Console logging should be on.
2. There is a little button(that is accessible with a pen/needle) next to
the console port on the supervisor this is to change the pinout for the
console cable to modem cable. Make sure your using the right type of
console cable(usually green x-over). You should at least see the rommon
boot process even if console logging is not enabled.
-Sam

----- Original Message -----
From: <Hemant_Kumar@BERLEX.COM>
To: "Ma Gang" <matthen@zisco.com.cn>
Cc: <ccielab@groupstudy.com>
Sent: Friday, April 05, 2002 2:07 PM
Subject: Re: Catalyst 6506 problem

Matthew

Make sure you have logging console enabled.

Set logging console enable

HTH
Hemant

                    Ma Gang
                    <matthen@zisc
                    o.com.cn> To: ccielab@groupstudy.com
                                  cc: (bcc: Hemant Kumar/RM/USR/SHG)
                    04/04/02 Subject:
                    09:53 PM Catalyst 6506 problem
                    Please
                    respond to Ma
                    Gang

Dear All,

We meet a Catalyst 6506 problem here. The symptom is the CONSOLE shows
nothing when the 6506 is booting. The console is configed as 9600/8/N/1. No
matter how I press the keyboard, it still shows nothing.

Anyone here met this problem before, and how to solve it?

Thanks in advance.

Regards

Matthew Ma