From: Ouellette, Tim (tim.ouellette@xxxxxxx)
Date: Wed Jul 03 2002 - 02:39:42 GMT-3
Had a ameritech technician trying to troubleshoot a a connection from 1
router to another. They were able to loop the smartjack at the remote site
(where the following show commands are from the router) but were unable to
loop the built in csu/dsu in the 7204. The only odd part of this is that
there 3 T1's multilinked together in this configuration. Can anyone
provide any insight?
Router is a cisco 7204 with 12.1(5a)
routera#sh controller t1 1/0
T1 1/0 is up.
Applique type is Channelized T1
Cablelength is long gain36 0db
Description: T1 to xxxx serial 1/0
No alarms detected.
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (17 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
router#sh int s1/0:1
Serial1/0:1 is up, line protocol is up
Hardware is Multichannel T1
This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:36:17 GMT-3