From: kris.keen@xxxxxxxxxx
Date: Thu Aug 08 2002 - 22:10:24 GMT-3
   
Are you sure you configured your frame relay switch correctly? you may have
the wrong dlci setup on each interface on the switch
this has happened to me before..
-----------------------------------------------------------------
Kris Keen - CCNP, CCDP, CNE
Network Support Specialist - Network Systems
Aon Risk Services Australia Limited
(612) 9253 7272
0404862970
E: Kris.Keen@aon.com.au
                    syv
                    <syv@911networ       To:     ccielab@groupstudy.com
                    ks.com>              cc:
                    Sent by:             bcc:
                    nobody@groupst       Subject:     Wrong DLCI showing up on
DTEs
                    udy.com
                    09/08/2002
                    10:22 AM
                    Please respond
                    to syv
Hi ccielab,
when displaying the PVC on the DTE routers I get the wrong PVC.
Any suggestion?
Here is the config, and the show frame pvc.
C1751[S0/1]-----100-[S1]FR-SWITCH[S2]-101-----[S0]C2502
This is one of the most minimal config:
FR-Switch
frame-relay switching
interface Serial1
 no ip address
 encapsulation frame-relay
 clockrate 56000
 frame-relay intf-type dce
 frame-relay route 100 interface Serial2 101
!
interface Serial2
 no ip address
 encapsulation frame-relay
 clockrate 56000
 frame-relay intf-type dce
 frame-relay route 101 interface Serial1 100
!
c1720#sh fram pvc
PVC Statistics for interface Serial1 (Frame Relay DCE)
            Active     Inactive      Deleted       Static
  Local          0            0            0            0
  Switched       1            0            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = SWITCHED, PVC STATUS = ACTIVE, INTERFACE = Serial1
  input pkts 7             output pkts 6            in bytes 588
  out bytes 554            dropped pkts 0           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 0          out bcast bytes 0            Num Pkts Switched
  6
  pvc create time 02:15:48, last time pvc status changed 02:12:09
PVC Statistics for interface Serial2 (Frame Relay DCE)
            Active     Inactive      Deleted       Static
  Local          0            0            0            0
  Switched       1            0            0            0
  Unused         0            0            0            0
DLCI = 101, DLCI USAGE = SWITCHED, PVC STATUS = ACTIVE, INTERFACE = Serial2
  input pkts 6             output pkts 6            in bytes 554
  out bytes 554            dropped pkts 1           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 0          out bcast bytes 0            Num Pkts Switched
  6
  pvc create time 02:15:00, last time pvc status changed 02:11:00
================================
DTE#1 should be DLCI 100 and NOT 101
hostname c1751
interface Serial0/1
 ip address 192.168.10.1 255.255.255.0
 encapsulation frame-relay
c1751#show frame pvc
PVC Statistics for interface Serial0/1 (Frame Relay DTE)
            Active     Inactive      Deleted       Static
  Local          1            0            0            0
  Switched       0            0            0            0
  Unused         0            0            0            0
DLCI = 101, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/1
  input pkts 6             output pkts 6            in bytes 554
  out bytes 554            pkts dropped in 0
  pkts dropped out 0       dropped bytes out 0
  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 1         out bcast bytes 34
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
  pvc create time 02:14:17, last time pvc status changed 02:12:47
================================
DTE# 2 should be DLCI 101 and NOT 100
hostname c2502
interface Serial0
 ip address 192.168.10.3 255.255.255.0
 encapsulation frame-relay
c2502#sh fram pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
            Active     Inactive      Deleted       Static
  Local          1            0            0            0
  Switched       0            0            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0
  input pkts 6             output pkts 6            in bytes 554
  out bytes 554            dropped pkts 0           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 1          out bcast bytes 34
  pvc create time 02:14:31, last time pvc status changed 02:14:31
c2502#
Thanks
---- syv@911networks.com
This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:48:21 GMT-3