From: Jack DeLaGarza (bluspooky@xxxxxxxxx)
Date: Tue Aug 13 2002 - 11:52:08 GMT-3
   
maybe I'm missing something, but shouldn't you have a
'dialer wait-for-carrier x' statement under the
calling router config and 'dialer enable-timeout 1/2
of x' under the called router's config?
--- Semion Lisyansky <semionl@yahoo.com> wrote:
> Hi List,
>
> I'm triying to configure ISDN callback on
> a single ISDN line connected to two routers.
> It looks like the authentication passes OK,
> but then nothing happened - no call back.
> My configs:
>
> Calling party:
> !
> hostname 2504-1
> !
> username 2503-2 password 0 cisco
> !
> interface BRI0
>  no ip address
>  encapsulation ppp
>  no keepalive
>  dialer pool-member 1
>  isdn switch-type basic-net3
>  isdn answer1 XXXX
>  isdn answer2 XXXX
>  cdapi buffers regular 0
>  cdapi buffers raw 0
>  cdapi buffers large 0
>  no cdp enable
>  ppp callback request
>  ppp authentication pap
> !
> interface Dialer1
>  ip address 192.168.120.21 255.255.255.248
>  encapsulation ppp
>  no keepalive
>  dialer pool 1
>  dialer idle-timeout 50
>  dialer string YYYY
>  dialer-group 1
>  pulse-time 0
>  ppp callback request
>  ppp authentication pap
>  ppp pap sent-username 2504-1 password 7
> 00071A150754
> !
> dialer-list 1 protocol ip permit
> !
This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:48:24 GMT-3