From: Gareth Bromley (gbromley@intstar.com)
Date: Sun Dec 08 2002 - 08:37:59 GMT-3
Thanks for the hints, but still no joy.
Tried 9600 8N2, even parity, marked etc both with 1 and 2 stop bits, and
still no joy.
Anyone got any other thoughts?
Cheers
Gareth
----- Original Message -----
From: "Georg Pauwen" <pauwen@hotmail.com>
To: <gbromley@intstar.com>; <ccielab@groupstudy.com>
Sent: Sunday, December 08, 2002 8:56 AM
Subject: Re: Lightstream LS100 funnies
> GHi Gareth,
>
> try Console port set for 9600 baud, 8 data bits, 2 stop bits, no parity,
see
> if this works.
>
> Regards,
>
> Georg
>
>
> >From: "Gareth Bromley" <gbromley@intstar.com>
> >Reply-To: "Gareth Bromley" <gbromley@intstar.com>
> >To: <ccielab@groupstudy.com>
> >Subject: Lightstream LS100 funnies
> >Date: Sun, 8 Dec 2002 07:14:54 -0000
> >
> >As subject:
> >
> >Recently picked up a LS100 with OC3 and T3 ATM mods. The unit boots fine
> >and
> >displays to terminal across standard Cisco cable with cisco DB9
connectors
> >(male on LS100, female on PC). However, when I press any key nothing
> >happens.
> >I've tried both console ports on the LS100.
> >
> >The terminal settings are 9600 8N1 and I've tried flow control on/off,
> >hardware none etc.. all to no avail. This kid of makes me think its
either:
> >- Wrong cable?? missing say a transmit?
> >- Faulty unit?
> >
> >Any thoughts
> >
> >Gareth
> >.
> _________________________________________________________________
> Protect your PC - get McAfee.com VirusScan Online
> http://clinic.mcafee.com/clinic/ibuy/campaign.asp?cid=3963
> .
.
This archive was generated by hypermail 2.1.4 : Fri Jan 17 2003 - 17:21:40 GMT-3