From: Janto Cin (jantocin@datacomm.co.id)
Date: Wed Jan 15 2003 - 00:26:08 GMT-3
Hi Fabrice,
I've tried the configuration below on my lab and it didn't work.
But it work by using ilmi w/ esi-address.
Is it depend on how we configure the atm switch?
Because it also happen when I configure SVC CLIP w/o ilmi.
TIA.
Janto
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Fabrice Bobes
Sent: Tuesday, January 14, 2003 11:46 PM
To: 'Hunt Lee'
Cc: ccielab@groupstudy.com
Subject: RE: Help Help!!! ATM question
Lee,
No, you don't need it.
This SVC configuration will work without ilmi:
Int ATM 2/0
Ip add 10.10.10.2 255.255.255.0
Pvc 0/5 qsaal
Atm nsap-address 47.009181000000123456789012.1414.1414.1414.00
Svc svc-1 nsap 47.009181000000123456789012.1313.1313.1313.00
Protocol ip 10.10.10.1 br
Regards,
Fabrice
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Hunt Lee
Sent: Monday, January 13, 2003 10:47 PM
To: 'ccielab@groupstudy.com'
Subject: Help Help!!! ATM question
For ATM SVCs (assuming I'm not using Classical IP), is it true that
regardless of whether I am using the ESI address OR NSAP address, I
still need to enable ILMI by 'pvc 0/16 ilmi' command?
Regards,
Lee
-- WebCentral Pty Ltd Australia's #1 Internet Web Hosting Company Level 1, 96 Lytton Road. Network Operations - Systems Engineer PO Box 4169, East Brisbane. email: huntl@webcentral.com.au Queensland, Australia. phone: +61 7 3249 2553 . .