From: MADMAN (dave@interprise.com)
Date: Wed Jun 11 2003 - 13:38:04 GMT-3
Yes, sup-slot0:
You can't view the slot0: of the sup card form the MSFC but you can
boot off of it. Here is my boot variable on the MSFC2:
boot system flash sup-slot0:c6msfc2-jk2o3sv-mz.121-13.E3.bin
Dave
Jung, Jin wrote:
> I came across this minor problem and could not find documentations.
>
> I have MSFC1 and SUP1 for 6500..
>
> And was trying to access the flash slot0: from MSFC so I can use the slot0:
> as backup.
>
> But I was not able to access the slot0: , and slot0: does not show up as
> flash device.
>
> I am able to access slot0: from sup1 module without any problem.
>
>
> Is there a special command that I can use to get access to slot0:
>
> Jin jung ...
>
>
-- David Madland CCIE# 2016 Sr. Network Engineer Qwest Communications 612-664-3367"Government can do something for the people only in proportion as it can do something to the people." -- Thomas Jefferson
This archive was generated by hypermail 2.1.4 : Fri Jul 04 2003 - 11:10:56 GMT-3