Re: OT:65XX mmfc recovery

From: Phil (ciscostudent1@yahoo.com.br)
Date: Thu Jul 31 2003 - 20:17:18 GMT-3


Todd,
 
Do you have MSFC14s or MSFC24s in the SUP14s?
What are the current and new CatOS and IOS versions for the sup4s and msfc4s?
I just went through an upgrade last night in 2 65094s and there are many factors to take into consideration.
 
Phil
 

Todd Veillette <tveillette@myeastern.com> wrote:
All,

Redundant sup1's both with msfc. Long story short upgrading msfc,
with the boot image on bootflash and the catos in slot0.

Via reset, switch sup, and/or switch console I can see the msfc's request
as in:

tftp:\\255.255.255.255\slot0:msfc_12.whatever.bin

which results in error opening tftp. I'm guessing the "slot0"
shouldn't be there, as this isn't part of the image's name.

Change the name to above - will it work?

If not, I think I need to bootrom chip and clear the bootldr and bootflash?

Oh the main problem here is my outage window is 1 hour if I'm lucky,
once a week.

Any feedback would be appreciated.

-TV



This archive was generated by hypermail 2.1.4 : Wed Aug 06 2003 - 06:53:00 GMT-3