From: Jean-Francois Vaillancourt (hans@cam.org)
Date: Sat Aug 07 2004 - 10:37:48 GMT-3
At 06/08/2004, Alexander Arsenyev (GU/ETL) wrote:
>Quick search on CCO reveals that Catalyst 6000 could do "microflow
>policing" but one still needs to
>define an ACL for every host, see
>http://www.cisco.com/warp/public/473/102.html#fourth .
With the Sup720, you can do user-based rate-limiting. In a nutshell, the
ACLs are created dynamically, scales much better :)
See http://www.cisco.com/warp/public/cc/pd/si/casi/ca6000/prodlit/2103_pp.pdf
HTH
JF #11874
This archive was generated by hypermail 2.1.4 : Fri Sep 03 2004 - 07:02:34 GMT-3