From: Schulz, Dave (DSchulz@dpsciences.com)
Date: Mon Mar 20 2006 - 10:52:56 GMT-3
Steve -
I have not seen this specific lab, but there is a way to learn the
specific dlci dynamically on a point-to-point by eliminating all the
other dlci's that might exist on that link, by using the command, "no
frame-relay interface-dlci xxx". Kind of a backwards of doing things
but it takes care of labs that say you cannot use the frame map or
specifically define a dlci. Hope this helps.
Dave Schulz,
Email: dschulz@dpsciences.com
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Stephen Vallois-Davies
Sent: Monday, March 20, 2006 2:51 AM
To: ccielab@groupstudy.com
Subject: stuck on frame-relay q !
Hi,
how can I dynamically learn addresses through inverse-arp on specific
DLCI's
- without using the no frame-relay inverse-arp command?
Specifically I have been scratching my head over q2.2 (Vol2Lab4 IEWB 3).
It shows the dlci's as dynamically learned, yet prohibits the use of 'no
frame-relay inverse-arp' command
i.e
Serial0/0 (up): ip 152.4.123.3 dlci 203(0xCB,0x30B0), dynamic,
broadcast,, status defined, active
Thanks, Steve.