From: Mohamed T. Kondela (mtaib@sagia.gov.sa)
Date: Tue Jan 16 2007 - 15:43:01 ART
I do have a question in the Same lab, solution guide ask you to shut
down fa 0/21 on SW4, fine. But in reality, it is routed port and
connected to VLAN 107 across the domain to Sw1's fa 0/14. How can you
ping a interface if you shut down ? quite strange!
Regards
Mohamed T. Kondela
Senior Network Engineer
IT Dept.
Fax: 4473037 x 303
mtaib@sagia.gov.sa
Saudi Arabian General Investment Authority
--------------------------------------------------------
This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version.
--------------------------------------------------------
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Brian Dennis
Sent: Tuesday, January 16, 2007 6:44 PM
To: dampened; Cisco certification
Subject: RE: IEWBv4 Lab1 1.2
Task 1.2 states to "ensure that other ports never become trunk ports".
This means the solution is really going to depend on what hardware you
did the lab with (four 3560s or three 3560s and one 3550). In the
latter case you could shutdown any extra inter-switch links connected to
the 3550 since they are in dynamic desirable mode. You could also
change the mode (either side) as opposed to shutting down the interface.
If using all 3560s nothing would need to be done since they are in
dynamic auto mode.
Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP)
bdennis@internetworkexpert.com
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
dampened
Sent: Tuesday, January 16, 2007 12:13 AM
To: Cisco certification
Subject: IEWBv4 Lab1 1.2
I did not find any thing on the question 1.2 that F0/21 between SW4 and
SW3
should be shutdown. However, the solution guilde have them shut. Is this
an
error?
Same go to links between SW1 and SW2. The connections between this two
switches are 2 x trunk (F0/13 and F0/15) and one access link (F0/14).
Is
this correct.
This archive was generated by hypermail 2.1.4 : Thu Feb 08 2007 - 23:46:56 ART