RE: VTP VERSION2 issue in TRANSPARENT MODE SWITCH

From: Usankin, Andrew (Andrew.Usankin@twtelecom.com)
Date: Thu Aug 30 2007 - 15:43:27 ART


Delete vlan.dat and reboot switch. Don't see any other way.

Andrew

________________________________

From: Eagle [mailto:ddycus@gmail.com]
Sent: Thursday, August 30, 2007 12:22 PM
To: Usankin, Andrew
Cc: ccielab@groupstudy.com
Subject: Re: VTP VERSION2 issue in TRANSPARENT MODE SWITCH

Agreed, Dynagen works fine with SW2-SW1-SW3 where SW1 is transparent and
in a different domain than SW2 (server) and SW3 (client) (including
null).

Quick related question though, how can I reset the domain on a switch
when managing vtp settings from VLAN DATABASE?

Thx,
-Eagle

On 8/30/07, Usankin, Andrew <Andrew.Usankin@twtelecom.com> wrote:

        I didn't mean to mislead any one. Alexey thank you for providing
us with
        a very helpful information. My point is that documentation is
fine, and
        switch modules behave according to the documentation. It is
seems to be
        a bug in "real" switches code releases :)
        So if I see next time that transparent switch in the middle is
the
        problem for my VTP domain I know what to do:
        1. Reset transparent switch's domain name to null or
        2. Put the same domain name on it as on rest of switches.

        Andrew.

        ________________________________

        From: Alexey Tolstenok [mailto: alextols@gmail.com
<mailto:alextols@gmail.com> ]
        Sent: Thursday, August 30, 2007 9:20 AM
        To: Usankin, Andrew
        Cc: ccielab@groupstudy.com
        Subject: Re: VTP VERSION2 issue in TRANSPARENT MODE SWITCH

        On "real" switches the behaviour is the same as described in
original
        post

        2007/8/30, Usankin, Andrew <Andrew.Usankin@twtelecom.com >:

                I have labbed it on dynamips last night on 3725 routers
with
        NM-16ESW
                modules. All is working just fine. Doesn't matter if
middle
        switch has
                null domain name or specific domain name. Transparent
VTP v2
        forward all
                unknown VTP advertisements between edge switches just
fine, and
        v1 drops
                everything. All behaves according documentation.

                See if you can find another image which doesn't have
this bug.

        --
        SY, Alexey

        The content contained in this electronic message is not intended
to
        constitute formation of a contract binding TWTC. TWTC will be
        contractually bound only upon execution, by an authorized
officer, of
        a contract including agreed terms and conditions or by express
        application of its tariffs.

        This message is intended only for the use of the individual or
entity
        to which it is addressed. If the reader of this message is not
the
        intended recipient, or the employee or agent responsible for
        delivering the message to the intended recipient, you are hereby
        notified that any dissemination, distribution or copying of this
        message is strictly prohibited. If you have received this
        communication in error, please notify us immediately by replying
to
        the sender of this E-Mail or by telephone.



This archive was generated by hypermail 2.1.4 : Sat Sep 01 2007 - 11:32:13 ART