From: mark.2.johnson@bt.com
Date: Mon Feb 25 2008 - 09:51:12 ARST
Hi Kevin,
 
I take it you've tried the three responses to your email?????
 
interface Serial3/0
 no ip address
 encapsulation frame-relay
 no keepalive < change to keepalive
 no fair-queue
 
HTH
 
Mark
 
 
________________________________
From: nobody@groupstudy.com on behalf of kevin.m.dalby@accenture.com
Sent: Sun 24/02/2008 17:26
To: ccielab@groupstudy.com
Subject: Fame Relay DLCI INACTIVE / Interface down down
Hi All,
Can someone verify this config for me, I just added a frame relay switch
to my lab, and can't get frame working on one of the interfaces up.
I also tried moving to dif slots on the FRSW, used dif cables and with
dif routers, still doesn't work.
All suggestions appreciated. Thanks!
R6 <-FRSW-> BB1
Rack1R6#sh ip int brie
Interface                  IP-Address      OK? Method Status
Protocol
Ethernet0/0                140.1.100.6     YES manual up
up
Ethernet1/0                unassigned      YES unset  administratively
down down
Serial3/0                  unassigned      YES manual down
down
Serial3/0.1                54.1.2.6        YES manual down
down
Rack1R6# sh run
interface Serial3/0
 no ip address
 encapsulation frame-relay
 no keepalive
 no fair-queue
!
interface Serial3/0.1 point-to-point
 ip address 54.1.2.6 255.255.255.0
 frame-relay interface-dlci 100
!
Rack1R6#sh frame pvc
PVC Statistics for interface Serial3/0 (Frame Relay DTE)
              Active     Inactive      Deleted       Static
  Local          0            0            0            1
  Switched       0            0            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = LOCAL, PVC STATUS = STATIC, INTERFACE =
Serial3/0.1
  input pkts 0             output pkts 0            in bytes 0
  out bytes 0              dropped pkts 0           in pkts dropped 0
  out pkts dropped 0                out bytes dropped 0
  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 0         out bcast bytes 0
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
  pvc create time 04:08:43, last time pvc status changed 03:30:45
Rack1R6#sh frame map
Serial3/0.1 (down): point-to-point dlci, dlci 100(0x64,0x1840),
broadcast
BB1#sh ip int brie
Interface                  IP-Address      OK? Method Status
Protocol
Serial0/0.100              54.1.2.254      YES NVRAM  down
down
BB1#sh run int s0/0.100
interface Serial0/0.100 point-to-point
 description PVC 100 to Rack8
 ip address 54.1.2.254 255.255.255.0
 ipv6 address 2001:54:1:2::254/64
 ipv6 address FE80::254 link-local
 frame-relay interface-dlci 100
BB1#sh frame pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
              Active     Inactive      Deleted       Static
  Local          0            6            0            0
  Switched       0            0            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = LOCAL, PVC STATUS = INACTIVE, INTERFACE =
Serial0/0.100
  input pkts 0             output pkts 1037         in bytes 0
  out bytes 96114          dropped pkts 0           in pkts dropped 0
  out pkts dropped 0                out bytes dropped 0
  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 940       out bcast bytes 90416
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
  pvc create time 4d06h, last time pvc status changed 00:40:57
BB1#sh frame map
Serial0/0.100 (down): point-to-point dlci, dlci 100(0x64,0x1840),
broadcast
          status defined, inactive
FRSW# sh run
interface Serial6
 description Connected to Rack1R6
 no ip address
 encapsulation frame-relay
 clockrate 64000
 frame-relay intf-type dce
 frame-relay route 51 interface Serial9 51
 frame-relay route 100 interface Serial9 100
 frame-relay route 101 interface Serial9 101
 frame-relay route 201 interface Serial9 201
 frame-relay route 301 interface Serial9 301
 frame-relay route 401 interface Serial9 401
!
interface Serial7
 no ip address
 shutdown
!
interface Serial8
 no ip address
 shutdown
!
interface Serial9
 description Connected to BB1
 no ip address
 encapsulation frame-relay
 clockrate 64000
 frame-relay intf-type dce
 frame-relay route 51 interface Serial6 51
 frame-relay route 100 interface Serial6 100
 frame-relay route 101 interface Serial6 101
 frame-relay route 201 interface Serial6 201
 frame-relay route 301 interface Serial6 301
 frame-relay route 401 interface Serial6 401
fra# sh ip int brie
Interface                  IP-Address      OK? Method Status
Protocol
Serial4                    unassigned      YES unset  up
up
Serial5                    unassigned      YES unset  up
up
Serial6                    unassigned      YES unset  down
down
Serial7                    unassigned      YES manual administratively
down down
Serial8                    unassigned      YES manual administratively
down down
Serial9                    unassigned      YES unset  up
up
PVC Statistics for interface Serial6 (Frame Relay DCE)
              Active     Inactive      Deleted       Static
  Local          0            0            0            0
  Switched       0            6            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = SWITCHED, PVC STATUS = INACTIVE, INTERFACE =
Serial6
  input pkts 0             output pkts 0            in bytes 0
  out bytes 0              dropped pkts 0           in pkts dropped 0
  out pkts dropped 0                out bytes dropped 0
  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 0         out bcast bytes 0
  switched pkts 0
  Detailed packet drop counters:
  no out intf 0            out intf down 0          no out PVC 0
  in PVC down 0            out PVC down 0           pkt too big 0
  shaping Q full 0         pkt above DE 0           policing drop 0
  pvc create time 00:49:40, last time pvc status changed 00:43:39
PVC Statistics for interface Serial9 (Frame Relay DCE)
              Active     Inactive      Deleted       Static
  Local          0            0            0            0
  Switched       0            6            0            0
  Unused         0            0            0            0
DLCI = 100, DLCI USAGE = SWITCHED, PVC STATUS = INACTIVE, INTERFACE =
Serial9
  input pkts 14            output pkts 0            in bytes 1446
  out bytes 0              dropped pkts 0           in pkts dropped 0
  out pkts dropped 0                out bytes dropped 0
  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 0         out bcast bytes 0
  switched pkts 0
  Detailed packet drop counters:
  no out intf 0            out intf down 0          no out PVC 0
  in PVC down 0            out PVC down 0           pkt too big 0
  shaping Q full 0         pkt above DE 0           policing drop 0
  pvc create time 00:49:32, last time pvc status changed 00:43:42
This archive was generated by hypermail 2.1.4 : Sat Mar 01 2008 - 16:54:49 ARST