Hi Experts
I have a strange issue here, maybe im missing something obvious...?
*Cat1-MST#sh int trunk *
Port        Mode             Encapsulation  Status        Native vlan
Fa0/19      desirable        802.1q         trunking      1
Fa0/20      desirable        802.1q         trunking      2
Fa0/21      desirable        802.1q         trunking      3
Fa0/22      desirable        802.1q         trunking      4
Fa0/23      desirable        802.1q         trunking      5
Fa0/24      desirable        802.1q         trunking      6
Gi0/1       desirable        802.1q         trunking      15
*Cat2-MST#sh int trunk *
Port        Mode             Encapsulation  Status        Native vlan
Fa0/19      desirable        802.1q         trunking      7
Fa0/20      desirable        802.1q         trunking      8
Fa0/21      desirable        802.1q         trunking      9
Fa0/22      desirable        802.1q         trunking      10
Fa0/23      desirable        802.1q         trunking      5
Fa0/24      desirable        802.1q         trunking      6
Gi0/1       desirable        802.1q         trunking      15
*Cat3-MST#sh int trunk *
Port        Mode             Encapsulation  Status        Native vlan
Gi1/0/23    desirable        802.1q         trunking      13
Gi1/0/24    desirable        802.1q         trunking      14
*Cat4-MST#sh int trunk *
Port        Mode             Encapsulation  Status        Native vlan
Gi1/0/19    desirable        802.1q         trunking      1
Gi1/0/23    desirable        802.1q         trunking      13
Gi1/0/24    desirable        802.1q         trunking      14
Cats 1 & 2 are both 3560's running ADVIPSERVICESK9-M Version 12.2(46)SE
Cats 3 & 4 are both 3750X's running UNIVERSALK9-M Version 12.2(58)SE1
All trunks are in desirable mode, have tried different combo's none seem to
show the trunks in 3750x's sh int trunk list..
This only seems to happen when I change on-a-per-trunk-basis the *Native
vlan* i.e Cat 4 g1/0/20 going to Cat 1 f0/20 is now native vlan 2
*
*
using the default CDPv2 I would always get CDP native vlan mismatch syslog
messages on the 3560's (not on the 3750x's) only by changing to CDPv1 on
all switches did I clear this....
(On the 3560's you can see that it see's the trunks as up facing the
3750x's switches - and on the 3750x's the interfaces are up/up with packets
moving)
Is this simply a bug iv hit?
-- BR Tony Blogs and organic groups at http://www.ccie.netReceived on Wed Sep 19 2012 - 10:47:46 ART
This archive was generated by hypermail 2.2.0 : Mon Oct 01 2012 - 06:40:29 ART