Gents,
I tried a simple INE topology for OTV
Server1----5k1---7K1(OTV)----------7K2(OTV)----5K2---Server2
I can't bring-up OTV even with a very simple config.
Reason :- Site Vlan down ( Local device is not AED-Capable (Site-VLAN is
Down))
I can't understand this behavior as AED is somehow required on a dual edge
set-up. Please advice what's that I'm doing wrong. Following are the
configs and some show command outputs.
--
--Larry
------------LOGS-----------------
sh run otv
!Command: show running-config otv
!Time: Mon Apr 14 09:46:44 2014
version 6.2(2)
feature otv
otv site-vlan 888
interface Overlay1
otv join-interface Ethernet1/1
otv control-group 224.1.1.1
otv data-group 232.1.1.0/24
otv extend-vlan 20
no shutdown
otv site-identifier 0x101
N7K1#
N7K1# sh run int e1/1
!Command: show running-config interface Ethernet1/1
!Time: Mon Apr 14 09:48:09 2014
version 6.2(2)
interface Ethernet1/1
mtu 9100
ip address 169.254.0.71/24
ip igmp version 3
no shutdown
N7K1#
N7K1#
N7K1#
N7K1#
N7K1# sh otv adja Overlay Adjacency database
Overlay-Interface Overlay1 :
Hostname System-ID Dest Addr Up Time
State
N7K2 0026.980c.2143 169.254.0.72 00:04:47
UP
N7K1#
N7K1# sh otv site
Dual Adjacency State Description
Full - Both site and overlay adjacency up
Partial - Either site/overlay adjacency down
Down - Both adjacencies are down (Neighbor is down/unreachable)
(!) - Site-ID mismatch detected
Local Edge Device Information:
Hostname N7K1
System-ID 68bd.abd7.6044
Site-Identifier 0000.0000.0101
Site-VLAN 888 State is Down
Site Information for Overlay1:
Local device is not AED-Capable (Site-VLAN is Down)
Neighbor Edge Devices in Site: 0
Hostname System-ID Adjacency- Adjacency-
AED-
State Uptime
Capable
-----------------------------------------------------------------------------
---
[7m--More--[m
[K
N7K1#
N7K1#
N7K1#
=============================================================================
==
sh run otv
!Command: show running-config otv
!Time: Mon Apr 14 09:43:54 2014
version 6.2(2)
feature otv
otv site-vlan 888
interface Overlay1
otv join-interface Ethernet1/1
otv control-group 224.1.1.1
otv data-group 232.1.1.0/24
otv extend-vlan 20
no shutdown
otv site-identifier 0x102
N7K2#
N7K2# sh otv adj Overlay Adjacency database
Overlay-Interface Overlay1 :
Hostname System-ID Dest Addr Up Time
State
N7K1 68bd.abd7.6044 169.254.0.71 00:05:34
UP
N7K2#
N7K2# sh int e1/1
!Command: show running-config interface Ethernet1/1
!Time: Mon Apr 14 09:44:20 2014
version 6.2(2)
interface Ethernet1/1
mtu 9100
ip address 169.254.0.72/24
ip igmp version 3
no shutdown
N7K2#
N7K2# sh otv site
Dual Adjacency State Description
Full - Both site and overlay adjacency up
Partial - Either site/overlay adjacency down
Down - Both adjacencies are down (Neighbor is down/unreachable)
(!) - Site-ID mismatch detected
Local Edge Device Information:
Hostname N7K2
System-ID 0026.980c.2143
Site-Identifier 0000.0000.0102
Site-VLAN 888 State is Down
Site Information for Overlay1:
Local device is not AED-Capable (Site-VLAN is Down)
Neighbor Edge Devices in Site: 0
Hostname System-ID Adjacency- Adjacency-
AED-
State Uptime
Capable
-----------------------------------------------------------------------------
---
[7m--More--[m
[K
N7K2#
N7K2#
Blogs and organic groups at http://www.ccie.net
Received on Mon Apr 14 2014 - 23:01:08 ART
This archive was generated by hypermail 2.2.0 : Thu May 08 2014 - 13:53:43 ART