RE: Need help.

From: louie kouncar (lkouncar@xxxxxx)
Date: Fri Jun 01 2001 - 19:03:36 GMT-3


   
Very quick...

Use a floating Static with admin distance above 90 to the other netwroks via
the T1, the router will not use this because it sees the Eigrp route which
has a lower distance, once that route goes down, then the router will use
the T1...

Hope that helps, It's been a long day
............................................

Louie J. Kouncar
TCO3 Senior Data Center Engineer
UUNET
W-703-343-6645
C-703-304-2460

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Rajeev Siddappa
Sent: Friday, June 01, 2001 5:26 PM
To: ccielab@groupstudy.com
Subject: Need help.

hey guys,

I have a 11 mb microwave connection to other site.
The microwave link box is connect to the network
using an ethernet connection.

There is a T1 link whcih acts as an back up for the
microwave. the ciso router is runnig EIGRP.

can any one suggest how to bring up the seriaal link
with T1 circut up once the microwave goes down.

pls suggest me some thing.

with regards,
Rajeev.



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:31:16 GMT-3