From: marvin greenlee (marvin@ccbootcamp.com)
Date: Thu Jun 16 2005 - 22:51:47 GMT-3
If you're doing back to back ATM, your PVC needs to match on both sides.
Marvin Greenlee, CCIE#12237, CCSI# 30483
Network Learning Inc
marvin@ccbootcamp.com
www.ccbootcamp.com (Cisco Training)
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
sergehh@hotmail.com
Sent: Thursday, June 16, 2005 5:59 PM
To: ccielab@groupstudy.com
Subject: ATM Back to back configuration on 1401 Routers [bcc][faked-from]
Importance: Low
Hi,
 I need some help in configuring  a back to back atm, on 1401 routers
 I have connected a crossover cat5 to both ends of the atm0 and configuerd 
 using the following steps, lines keep going up and down.tried encap
aal5snap.
 any solutions will be greatley appreciated.
Thanks
 
R1
  interface ATM0
 ip address 192.1.1.1 255.255.255.0
 no ip directed-broadcast
 atm vc-per-vp 4096
 no atm ilmi-keepalive
 pvc 0/101 
  protocol ip 192.1.1.2 broadcast
  
 R2
interface ATM0
 ip address 192.1.1.2 255.255.255.0
 no ip directed-broadcast
 atm vc-per-vp 4096
 no atm ilmi-keepalive
 pvc 0/102 
  protocol ip 192.1.1.1 broadcast